{"id":2916,"date":"2026-01-23T11:17:38","date_gmt":"2026-01-23T03:17:38","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=2916"},"modified":"2026-01-23T11:17:39","modified_gmt":"2026-01-23T03:17:39","slug":"tu1000-benchtop-turbidity-meter","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/tu1000-benchtop-turbidity-meter\/","title":{"rendered":"TU1000 Benchtop Turbidity Meter"},"content":{"rendered":"<h5 class=\"wp-block-heading\">General Features<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">1-7 points calibration using Formazin standards or zero water<br>Autoranging from 0-1000 NTUs<br>Data capacity of up to 2000 sets (GLP-compliant)<br>Data stored can be transferred into the computer by USB or RS-232 communication interface<br>850nm LED Light Source<br>Uses Nephelometric principle with 90\u00b0 detection<br>Meets ISO 7027 and offers consistent light source for higher accuracy<br>Selectable turbidity units, including the NTU, FNU and EBC<br>Settable parameters, including user ID, number of calibration points, data and time, etc<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"840\" height=\"302\" src=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-6.png\" alt=\"\" class=\"wp-image-2917\" srcset=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-6.png 840w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-6-300x108.png 300w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-6-768x276.png 768w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-6-18x6.png 18w\" sizes=\"(max-width: 840px) 100vw, 840px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Technical Parameters<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">\u6a21\u578b<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">TU1000<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"4\">Measuring Unit<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">(0&nbsp;~&nbsp;2&nbsp;~&nbsp;0.00) NTU<br>(20.0&nbsp;~&nbsp;200.0) NTU<br>(200 ~1000) NTU\\<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u00b12% of reading+0.02NTU<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Repeatability<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u22640.5%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Fluctuation<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u00b10.5% FS\/30min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"2\">General<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Power Supply<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">AC Adapter, 200-240 VAC input<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Dimension (mm)&amp; Weight (kg)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">330\u00d7250\u00d7130, 2.5<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>General Features 1-7 points calibration using Formazin standards or zero waterAutoranging from 0-1000 NTUsData capacity of up to 2000 sets (GLP-compliant)Data stored can be transferred into the computer by USB or RS-232 communication interface850nm LED Light SourceUses Nephelometric principle with 90\u00b0 detectionMeets ISO 7027 and offers consistent light source for higher accuracySelectable turbidity units, including [&hellip;]<\/p>","protected":false},"featured_media":2918,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[46],"class_list":["post-2916","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-electrochemical-instruments-and-water-quality-analyzers"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2916\/revisions"}],"predecessor-version":[{"id":2920,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2916\/revisions\/2920"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media\/2918"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=2916"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=2916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}