{"id":2869,"date":"2026-01-22T13:09:00","date_gmt":"2026-01-22T05:09:00","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=2869"},"modified":"2026-01-22T13:09:00","modified_gmt":"2026-01-22T05:09:00","slug":"kft-40vc-karl-fischer-titrator","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/kft-40vc-karl-fischer-titrator\/","title":{"rendered":"KFT-40VC Karl Fischer Titrator"},"content":{"rendered":"<h4 class=\"wp-block-heading\">Volumetric Karl Fischer Titration<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Support KF Titration Mode and Titer Detection Mode<br>Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals<br>Automatic\/manual background dri ft correction ensures accurate results<br>Selectable units including mg, mg\/L, %, ppm, etc<br>Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc<br>Store up to 200 titration data sets (GLP-compliant)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Coulometric Karl Fischer Titration<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Generator cell with diaphragm<br>Selectable units including \u00b5g, mg, %, ppm, mg\/L, \u00b5g\/mL, etc<br>Store up to 200 titration data sets (GLP-compliant)<br>Automatic\/manual background dri ft correction ensures accurate results<br>Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"806\" height=\"257\" src=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-1.png\" alt=\"\" class=\"wp-image-2870\" srcset=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-1.png 806w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-1-300x96.png 300w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-1-768x245.png 768w, https:\/\/youmescientific.com\/wp-content\/uploads\/2026\/01\/image-1-18x6.png 18w\" sizes=\"(max-width: 806px) 100vw, 806px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">General Features<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">LCD display screen<br>Volumetric KF Titration and Coulometric KF Titration are supported<br>Data can be easily transferred to printer via RS-232 communication interface<br>Titration methods, curves and results are displayed in detail<br>Data analysis feature helps user review and compare results<br>Reset feature automatically resumes all settings back to factory default options<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Technical Parameters<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u6a21\u578b<\/td><td class=\"has-text-align-center\" data-align=\"center\">KFT-40VC<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Volumetric Titration<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">(0.1mg~250)mg<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Polarization Current Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">1\u00b5pA0.2A: 50\u00b5pA1OpA<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Repeatability<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"6\">Coulometric Titration<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Range<\/td><td class=\"has-text-align-center\" data-align=\"center\">10\u00b5g~20mg<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Polarization Current Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.2\u00b5A<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Working Current<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,1.86, 5,10 \u00b5g (H,O)\/s for 10.72mA,20 mA,53.61mA, 107.2mA<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Working Current Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">ACCuraCy<\/td><td class=\"has-text-align-center\" data-align=\"center\">(5%+3) \u00b5g<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Repeatability<\/td><td class=\"has-text-align-center\" data-align=\"center\">3%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">General<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power Supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">AC Adapter,100-240 VAC input<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Dimensions<\/td><td class=\"has-text-align-center\" data-align=\"center\">340x400x400 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">10kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Volumetric Karl Fischer Titration Support KF Titration Mode and Titer Detection ModeFeatures of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicalsAutomatic\/manual background dri ft correction ensures accurate resultsSelectable units including mg, mg\/L, %, ppm, etcSettable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, [&hellip;]<\/p>","protected":false},"featured_media":2871,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[46],"class_list":["post-2869","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-electrochemical-instruments-and-water-quality-analyzers"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2869","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2869\/revisions"}],"predecessor-version":[{"id":2873,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2869\/revisions\/2873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media\/2871"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=2869"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=2869"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}