{"id":2805,"date":"2025-12-29T10:28:36","date_gmt":"2025-12-29T02:28:36","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=2805"},"modified":"2025-12-29T10:28:37","modified_gmt":"2025-12-29T02:28:37","slug":"aipol-jhd50-dropping-point-and-softening-point-tester","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/aipol-jhd50-dropping-point-and-softening-point-tester\/","title":{"rendered":"AIpol-JHD50 Dropping point and softening point tester"},"content":{"rendered":"<h5 class=\"wp-block-heading\">Applicable Standards<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Technical standards comply with ASTM(D3204, D3461, D3104, D3954, D6090), DIN(51801, 51920), GB\/T(2294-2019, 3498, 8728-1988)ISO (2176-1972, 4625-2) and Pharmacopoeia and other standards<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Field of Use<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Widely used in asphalt (especially high temperature asphalt), paraffin, resin, rosin, grease, Vaseline, ointment, ointment, suppository, ointment, grease and other composition control and quality testing. It can completely replace the traditional Uhler drop method and global method to determine the softening point, without glycerol, and the test accuracy is higher<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Innovation Points to Improve Efficiency<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Automatic integration, AI automatically sets parameters<br>Processing 2 samples at a time<br>High-definition video instead of traditional microscope visual<br>Data can be printed directly through the printer<br>Comply with 21CFR Part 11, Audit Trail, Pharmacopoeia and electronic signature<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">The Key Technical Indexes<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Temperature range<\/td><td class=\"has-text-align-center\" data-align=\"center\">Room temperature -400\u00b0C<\/td><\/tr><tr><td>Detection method<\/td><td class=\"has-text-align-center\" data-align=\"center\">Semi-automatic<\/td><\/tr><tr><td>Fat cup<\/td><td class=\"has-text-align-center\" data-align=\"center\">2 drip cups with 2.8mm ori\ufb01ce<\/td><\/tr><tr><td>2 cups of softening point with 6.35mm ori\ufb01ceProcessing capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">2 channels\/batch (two samples can be made atthe same time)<\/td><\/tr><tr><td>Temperature resolution<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.01\u00b0C<\/td><\/tr><tr><td>Heating rate<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1\u00b0C- 20\u00b0C (200 speed adjustable)<\/td><\/tr><tr><td>Temperature control mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">PID precise temperature control furnace body fully closed design<\/td><\/tr><tr><td>Segment temperature control<\/td><td class=\"has-text-align-center\" data-align=\"center\">Up to 10 segment temperature control<\/td><\/tr><tr><td>Accuracy (level 0.2, provide measurement reports)<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.2\u00b0C (&lt;250\u00b0C)&nbsp; \/&nbsp; \u00b10.4\u00b0C (&gt;250\u00b0C)<\/td><\/tr><tr><td>Repeatability<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1\u00b0C\/Min repeatability \u00b10.1\u00b0C<\/td><\/tr><tr><td>Magni\ufb01cation<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard 9 times other multiples can be set<\/td><\/tr><tr><td>Display mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.4 &#8220;FTF color touch color screen<\/td><\/tr><tr><td>Data storage<\/td><td class=\"has-text-align-center\" data-align=\"center\">64GB<\/td><\/tr><tr><td>Method<\/td><td class=\"has-text-align-center\" data-align=\"center\">600 sets<\/td><\/tr><tr><td>Experimental method lock<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>User management<\/td><td class=\"has-text-align-center\" data-align=\"center\">Have\/four level rights management<\/td><\/tr><tr><td>Audit Trail<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Electronic signature<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Custom method library<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Export \ufb01leVeri\ufb01cation Advanced Defense MD5<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Export in multiple \ufb01le formats<\/td><td class=\"has-text-align-center\" data-align=\"center\">PDF and ExcelData interface: USB RS232 SD Wi-Fi, RJ45, U disk<br>(PC software can be con\ufb01gured to upload test data)<\/td><\/tr><tr><td>Scanning gun<\/td><td class=\"has-text-align-center\" data-align=\"center\">Support scanning gun QR code directly input information<\/td><\/tr><tr><td>Packing size<\/td><td class=\"has-text-align-center\" data-align=\"center\">430*320*370mm<\/td><\/tr><tr><td>Power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">110-230V 50\/60HZ 120W<\/td><\/tr><tr><td>Gross weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.50kg<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Applicable Standards Technical standards comply with ASTM(D3204, D3461, D3104, D3954, D6090), DIN(51801, 51920), GB\/T(2294-2019, 3498, 8728-1988)ISO (2176-1972, 4625-2) and Pharmacopoeia and other standards Field of Use Widely used in asphalt (especially high temperature asphalt), paraffin, resin, rosin, grease, Vaseline, ointment, ointment, suppository, ointment, grease and other composition control and quality testing. It can completely replace [&hellip;]<\/p>","protected":false},"featured_media":2806,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[45,40],"class_list":["post-2805","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-dropping-point-and-softening-point-tester","product_category-physical-property-analysis-instrument"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2805","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2805\/revisions"}],"predecessor-version":[{"id":2808,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2805\/revisions\/2808"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media\/2806"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=2805"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=2805"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}