{"id":2771,"date":"2025-12-26T14:27:34","date_gmt":"2025-12-26T06:27:34","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=2771"},"modified":"2025-12-26T14:30:07","modified_gmt":"2025-12-26T06:30:07","slug":"aipol-m130-fully-automatic-video-melting-point-instrument","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/aipol-m130-fully-automatic-video-melting-point-instrument\/","title":{"rendered":"AIpol-M130 fully automatic video melting point instrument"},"content":{"rendered":"<h5 class=\"wp-block-heading\">Innovation Points to Improve Efficiency<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Automatic integration, AI automatically sets parameters<br>High automation integration, one-click measurement function<br>Melting point, boiling point, turbidity point, sliding point<br>Four samples (3 small and 1 large hole) were processed at a time<br>Fully automatic recording of melting range, initial melting and final melting<br>Equipped with high-definition camera lens module<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">The Key Technical Indexes<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Temperature range<\/td><td class=\"has-text-align-center\" data-align=\"center\">Room temperature-420\u00b0C<\/td><\/tr><tr><td>Test mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">Melting point, boiling point, turbidity point, sliding point<\/td><\/tr><tr><td>Test samples<\/td><td class=\"has-text-align-center\" data-align=\"center\">Cantest a variety of types of samples<\/td><\/tr><tr><td>Testing method<\/td><td class=\"has-text-align-center\" data-align=\"center\">Fully automatic (compatible with manual)<\/td><\/tr><tr><td>Processing capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 \/ batch (four samples can be made atthe same time)<\/td><\/tr><tr><td>Temperature resolution<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.01\u00b0C<\/td><\/tr><tr><td>Linear heating rate error<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b1 5%<\/td><\/tr><tr><td>Heating rate<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1\u00b0C &#8211; -20\u00b0C (200 adjustable)<\/td><\/tr><tr><td>Program segment temperature control<\/td><td class=\"has-text-align-center\" data-align=\"center\">Uup to 10 programmable gradient temperature control<\/td><\/tr><tr><td>Spectrum<\/td><td class=\"has-text-align-center\" data-align=\"center\">Any zoom is available to view any detail of the spectrum<\/td><\/tr><tr><td>Accuracy (JJG 701 standard 0.2 level, provide measurement report)<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b10.2\u00b0C&nbsp;(&nbsp;\u2264200\u00b0C\uff09\/&nbsp; \u00b10.4\u00b0C\uff08&gt;200\u00b0C\uff09<\/td><\/tr><tr><td>Repeatability<\/td><td class=\"has-text-align-center\" data-align=\"center\">Repetitive \u00b1 0.1\u00b0C at 0.1\u00b0C \/ Min<\/td><\/tr><tr><td>Magni\ufb01cation<\/td><td class=\"has-text-align-center\" data-align=\"center\">Standard with 9 times other multiples can be set<\/td><\/tr><tr><td>Display mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.4-inch FTF color touch color screen<\/td><\/tr><tr><td>Data storage<\/td><td class=\"has-text-align-center\" data-align=\"center\">128G<\/td><\/tr><tr><td>Map preservation<\/td><td class=\"has-text-align-center\" data-align=\"center\">40,000 groups<\/td><\/tr><tr><td>Experimental method<\/td><td class=\"has-text-align-center\" data-align=\"center\">2,000 sets<\/td><\/tr><tr><td>User management<\/td><td class=\"has-text-align-center\" data-align=\"center\">Have \/ four-level authority management<\/td><\/tr><tr><td>Audit tracking<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Electronic signature<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Custom method library<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Experimental method locking<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Export \ufb01leVeri\ufb01cation Advanced protection MD5<\/td><td class=\"has-text-align-center\" data-align=\"center\">Yes<\/td><\/tr><tr><td>Printing mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">WIFI print serial port printing<\/td><\/tr><tr><td>Multiple \ufb01le formats to export<\/td><td class=\"has-text-align-center\" data-align=\"center\">PDF and Excel<\/td><\/tr><tr><td>Data interface<\/td><td class=\"has-text-align-center\" data-align=\"center\">USB RS232 SD Wi-Fi, RJ 45, U disk<br>(The upper computer software can be con\ufb01gured to upload the test data)<\/td><\/tr><tr><td>Scanning the gun<\/td><td class=\"has-text-align-center\" data-align=\"center\">It supports scanning the QR code of the gun to directly input the information<\/td><\/tr><tr><td>Small capillary size<\/td><td class=\"has-text-align-center\" data-align=\"center\">Outer diameter:&nbsp;\u03c6&nbsp;1.4mm, inner diameter:&nbsp;\u03c6&nbsp;1.0mm<\/td><\/tr><tr><td>Large capillary size<\/td><td class=\"has-text-align-center\" data-align=\"center\">Outer diameter:&nbsp;\u03c6&nbsp;4.0mm, inner diameter::&nbsp;\u03c6&nbsp;3.8mm<\/td><\/tr><tr><td>Packing size<\/td><td class=\"has-text-align-center\" data-align=\"center\">O430 * 320 * 370mm<\/td><\/tr><tr><td>Power supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">110-230V 50 \/ 60HZ 120W<\/td><\/tr><tr><td>Gross weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.50kg<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Innovation Points to Improve Efficiency Automatic integration, AI automatically sets parametersHigh automation integration, one-click measurement functionMelting point, boiling point, turbidity point, sliding pointFour samples (3 small and 1 large hole) were processed at a timeFully automatic recording of melting range, initial melting and final meltingEquipped with high-definition camera lens module The Key Technical Indexes Temperature [&hellip;]<\/p>","protected":false},"featured_media":0,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[41,40],"class_list":["post-2771","product","type-product","status-publish","hentry","product_category-melting-point-apparatus","product_category-physical-property-analysis-instrument"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2771","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2771\/revisions"}],"predecessor-version":[{"id":2773,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2771\/revisions\/2773"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=2771"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=2771"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}