{"id":2064,"date":"2025-12-03T16:57:28","date_gmt":"2025-12-03T08:57:28","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=2064"},"modified":"2025-12-19T10:00:01","modified_gmt":"2025-12-19T02:00:01","slug":"fd-vertical-autoclave","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/fd-vertical-autoclave\/","title":{"rendered":"FD \u7acb\u5f0f\u9ad8\u538b\u706d\u83cc\u5668"},"content":{"rendered":"<h5 class=\"wp-block-heading\">Product Features<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Certified by SFDA with medical device registration and production license<br>Each sterilization stage is displayed with LED lights,making the sterilization process clear at a glance<br>Microcomputer intelligent control system,achieves fully automatic control of the sterilization process<br>System automatically monitors the discharge of cold air to ensure a pure steam sterilization environment and the best sterilization effect<br>Pulse method to completely purge out cold air.(SE\/SR only)<br>Up to 20 error information records can be stored,facilitating instrument management<br>Built in water tank for internal discharging of steam,effectively absorbing water vapor from exhaust process.(SE\/SR only)<br>Fully automatic drying function or semi-automatic drying function choice(SR only)<br>Fully automatic drying:Equipped with an air pump and a 0.2um air filter,it automatically starts drying after sterilization.<br>After sterilization,clean air will be put in to replace the wet air inside,so as to improve drying efficiency. (Fully automatic drying is an option for SR only)<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Safety Features<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Lid closing checking<\/strong><br>Machine can not start if lid is not locking well,the self-induction interlock device can avoid risk of misuse<br><strong>Unique anti-scald cover<\/strong><br>Nice look an davoid causing scald<br><strong>Triple protection for lack of water<\/strong><br>The bottom of the sterilization chamber is equipped with three different dry burning protection devices: liquid expansion type,copper temperature sensing type, and electric ion type(water level sensor), to avoid misjudg- ment caused by a single method<br><strong>Double protection for over pressure<\/strong><br>Mechanical pressure gauge and electric sensing system, once pressure is abnormal, system will cut power, release the pressure and send out alarm<br><strong>Auto trouble shooting<\/strong><br>System will monitor the working status,and will cut the power, send out alarm, and report the error information once any abnormal situation detected<br><strong>Safety test function<\/strong><br>Regular testing of system security and safety protection measures is possible<br><strong>Real time monitor<\/strong><br>System will monitor the lid locking, pressure and temperature status on a real time basis to guarantee the safe and successful work of the autoclave<br><strong>Electrical protection<\/strong><br>Equipped with a highly sensitive electrical protection system, effectively providing leakage protection, overcurrent and short-circuit protection<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Spare Parts Option<\/h5>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"855\" height=\"229\" src=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2025\/12\/image-4.png\" alt=\"\" class=\"wp-image-2065\" srcset=\"https:\/\/youmescientific.com\/wp-content\/uploads\/2025\/12\/image-4.png 855w, https:\/\/youmescientific.com\/wp-content\/uploads\/2025\/12\/image-4-300x80.png 300w, https:\/\/youmescientific.com\/wp-content\/uploads\/2025\/12\/image-4-768x206.png 768w, https:\/\/youmescientific.com\/wp-content\/uploads\/2025\/12\/image-4-18x5.png 18w\" sizes=\"(max-width: 855px) 100vw, 855px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Technical Data<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">\u6a21\u578b<\/td><td class=\"has-text-align-center\" data-align=\"center\">Basic<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">FD29SA<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD50SA<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD80SA<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD100SA<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Pulse<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">FD29SE<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD50SE<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD80SE<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD100SE<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Drying<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">FD50SR<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD80SR<\/td><td class=\"has-text-align-center\" data-align=\"center\">FD100SR<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Capacity (L)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">29&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">50&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">80&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">100&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Dimension (L*W*H)(mm)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">580x490x960<\/td><td class=\"has-text-align-center\" data-align=\"center\">580x490x1085<\/td><td class=\"has-text-align-center\" data-align=\"center\">730x625x1100<\/td><td class=\"has-text-align-center\" data-align=\"center\">730x625x 1200<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Chamber Dimension (Dia*H)(mm)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">\u03c6320&#215;378<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u03c6320&#215;725<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u03c6400x 700<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u03c6400&#215;800<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Power Requirements<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">220V\u00b110%&nbsp;&nbsp; 15A&nbsp; 50HZ\/60HZ<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">220V\u00b110%&nbsp;&nbsp; 25A&nbsp; 50HZ\/60HZ<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Rated Power (W)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">2600W<\/td><td class=\"has-text-align-center\" data-align=\"center\">2600W<\/td><td class=\"has-text-align-center\" data-align=\"center\">4600W<\/td><td class=\"has-text-align-center\" data-align=\"center\">4600W<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Sus304 Basket Size (pcs)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">(&nbsp;\u03c6298&#215;260) x1<\/td><td class=\"has-text-align-center\" data-align=\"center\">(&nbsp;\u03c6298&#215;195) x3<\/td><td class=\"has-text-align-center\" data-align=\"center\">(&nbsp;\u03c6360x 275) x2<\/td><td class=\"has-text-align-center\" data-align=\"center\">(&nbsp;\u03c6360&#215;215) x3<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Chamber Material<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">SUS304 stainless steel<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Sterilization Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">105\u00b0C ~ 135\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Sterilization Time Range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">1 ~ 300min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Pressure Gauge Range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">-0.1MPa ~ 0.5MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Pulse Times<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">0~9 times (SE\/SR only)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Exhaust Temperature Range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">73\u00b0C~104\u00b0C (SE\/SR only,liquid mode)105\u00b0C ~ 130\u00b0C (Solid mode)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Safety Valve Set Pressrue<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">0.29MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Drying<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">Drying temperature: 80\u00b0C ~ 160\u00b0C&nbsp; Drying time: 1 ~ 300 min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Sterilization Mode<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">Solid mode Liquid mode Sterilization+drying (SR only)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Controller<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">Microcomputer control system<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Safety Device<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\">Lid closing checking,over temperature protection system,dry scorch protection,over pressure protection,safety<br>valve,over current\/short circuit\/electric leakage protection,scald protection, automatic failure-inspection system<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"7\">Note: FD-SA&nbsp; has&nbsp; liquid&nbsp; mode,but&nbsp; can&nbsp; not&nbsp; preset&nbsp; the&nbsp; exhaust&nbsp; temperature&nbsp; for&nbsp; liquid&nbsp; mode<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Product Features Certified by SFDA with medical device registration and production licenseEach sterilization stage is displayed with LED lights,making the sterilization process clear at a glanceMicrocomputer intelligent control system,achieves fully automatic control of the sterilization processSystem automatically monitors the discharge of cold air to ensure a pure steam sterilization environment and the best sterilization effectPulse [&hellip;]<\/p>","protected":false},"featured_media":2070,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[32],"class_list":["post-2064","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-autoclave"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2064","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2064\/revisions"}],"predecessor-version":[{"id":2657,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/2064\/revisions\/2657"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media\/2070"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=2064"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=2064"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}