{"id":1858,"date":"2025-12-01T11:21:49","date_gmt":"2025-12-01T03:21:49","guid":{"rendered":"https:\/\/youmescientific.com\/?post_type=product&#038;p=1858"},"modified":"2025-12-19T09:25:19","modified_gmt":"2025-12-19T01:25:19","slug":"biosafety-cabinets-series-bsc-1300iib2","status":"publish","type":"product","link":"https:\/\/youmescientific.com\/zh\/products\/biosafety-cabinets-series-bsc-1300iib2\/","title":{"rendered":"\u751f\u7269\u5b89\u5168\u67dc\u7cfb\u5217 BSC-1300IIB2"},"content":{"rendered":"<h5 class=\"wp-block-heading\"><strong>Product Description<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Class II Biosafety Cabinet \u2013 100% exhaust airflow configuration<br>Meets Pharmaceutical Industry Standards of China (YY 0569-2011)<br>Certified by SFDA with medical device registration and production license<br>Outer shell made of high-quality cold-rolled steel with electrostatic spray coating; three sides of the operational area are formed with integrated stainless steel; internal parts feature 10 mm large rounded corners for easy cleaning<br>Dual HEPA filters with ULPA-level efficiency (\u226599.9995% at 0.12 \u00b5m), using partition-free borosilicate glass fiber membrane<br>High-quality, low-noise fan with automatic speed control; features high-sensitivity breeze speed sensor for real-time, pressure-free wind speed monitoring <br>Custom-developed software with national software copyright certification; LCD screen shows temperature, airflow, and other parameters; password-protected settings with blue screen digital display to prevent misoperation<br>Filter alarm: Real-time barcode display for filter life tracking, with sound and light alarms to prompt timely replacement<br>Equipped with upper and lower limit alarm system; sound and light alerts activate when the glass door exceeds or drops below set positions<br>Fully enclosed working area maintained under negative pressure on all sides to ensure zero leakage and maximum cleanliness<br>Integrated sliding door can be positioned freely; UV lamp functions only when the window is fully closed<br>6 mm thick safety-tempered glass used for the front window door<br>Automatically deactivates the UV germicidal lamp and activates the fan when the front window opens, ensuring safe and efficient operation<br>UV lamp features programmable reservation and timing functions<br>Includes a built-in spare power socket<br>10\u00b0 forward tilt enhances operator comfort and visibility during operation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Technical Parameters<\/strong><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><\/td><td>Parameters\/Model<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">BSC-1300IIB2<\/td><td><\/td><\/tr><tr><td><\/td><td>Cleanliness Level<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">HEPA ISO 4 (Class 10 Cleanroom)<\/td><td><\/td><\/tr><tr><td><\/td><td>Supply Air Velocity (m\/s)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">0.33\u00b10.025<\/td><td><\/td><\/tr><tr><td><\/td><td>In\ufb02ow Air Velocity (m\/s)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">0.53\u00b10.025<\/td><td><\/td><\/tr><tr><td><\/td><td>Noise (dB)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u226467<\/td><td><\/td><\/tr><tr><td><\/td><td>Vibration Semi-Peak Value (\u00b5m)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">\u22645<\/td><td><\/td><\/tr><tr><td><\/td><td>Voltage\/Maximum Power Consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">AC 220V\/50Hz\/1.5KW<\/td><td><\/td><\/tr><tr><td><\/td><td rowspan=\"2\">Personnel Biosecurity &amp; Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\" rowspan=\"2\">Impact sampler \u226410 CFU\/Slit sampler \u22645 CFU<\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><\/tr><tr><td><\/td><td>Product Biosecurity &amp; Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Petri dish samples \u22645 CFU<\/td><td><\/td><\/tr><tr><td><\/td><td>Cross-Contamination Protection<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Petri dish samples \u22642 CFU<\/td><td><\/td><\/tr><tr><td><\/td><td>Working Area Dimensions (mm)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">1300\u00d7520\u00d7640<\/td><td><\/td><\/tr><tr><td><\/td><td>Overall Dimension (mm)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">1465\u00d7760\u00d72200<\/td><td><\/td><\/tr><tr><td><\/td><td rowspan=\"2\">Illumination (LX)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\" rowspan=\"2\">\u2265900<\/td><td><\/td><\/tr><tr><td><\/td><td><\/td><\/tr><tr><td><\/td><td>Weight (kg)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">260&nbsp;<\/td><td><\/td><\/tr><tr><td><\/td><td>Number of Operators<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">1 or 2<\/td><td><\/td><\/tr><tr><td><\/td><td>Draft Direction<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Top<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><br><\/p>","protected":false},"excerpt":{"rendered":"<p>Product Description Class II Biosafety Cabinet \u2013 100% exhaust airflow configurationMeets Pharmaceutical Industry Standards of China (YY 0569-2011)Certified by SFDA with medical device registration and production licenseOuter shell made of high-quality cold-rolled steel with electrostatic spray coating; three sides of the operational area are formed with integrated stainless steel; internal parts feature 10 mm large [&hellip;]<\/p>","protected":false},"featured_media":1929,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"product_category":[21],"class_list":["post-1858","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-biosafety-cabinets"],"_links":{"self":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/1858","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/1858\/revisions"}],"predecessor-version":[{"id":2631,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product\/1858\/revisions\/2631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media\/1929"}],"wp:attachment":[{"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/media?parent=1858"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/youmescientific.com\/zh\/wp-json\/wp\/v2\/product_category?post=1858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}