General Features
High resolution LCD display, 5.7 inches
Multi-reading feature allows auto-read, timed-read and continuous-read
Automatic/Manual temperature compensation ensures accurate results
Auto-hold feature senses and locks the measurement endpoint
Data Storage 500 sets (GLP-compliant)
Support for USB or RS-232 communication
Reset feature automatically resumes all settings back to factory default options
IP54 waterproof

Ion
1-5 points calibration
Selectable measurement unit, including µg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc
Multi-measurement modes are supported, including Direct
Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode
Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3 -, BF4 -, NH4 +, K+ , Na+ , Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported
pH
1-5 points calibration with Standard Recognition
Selectable pH buffer groups, including NIST, DIN, GB, USA
Automatic electrode diagnosis with pH slope and offset display
Conductivity
1-3 points calibration with Standard Recognition
Temperature compensation type (none, linear, pure water)
Settable parameters, including cell constant, temperature compensation coefficient and TDS factor
DO
Support for air-saturated water or zero oxygen calibration
Manual Salinity Factor Correction
Selectable pressure unit, including kPa, mbar, Torr, Atm
Auto barometric pressure compensation
Technical Parameters
| 模型 | M300F | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.00 to 20.00pH |
| Resolution | 0.1, 0.01 pH | |
| Accuracy | ± 0.01 pH | |
| Calibration Points | Up to 5 | |
| Standard Customization | Yes | |
| Standard Recognition | NIST, GB, USA and DIN buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.0 to 2000.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | ± 0.3 mV or ± 0.1% | |
| pX | Range | -2.00 to 20.00 pX |
| Resolution | 0.1, 0.01 pX | |
| Accuracy | ± 0.01 pX | |
| Calibration Points | Up to 5 | |
| ISE | Range | 1.000e-9 to 9.999e+9 |
| Unit | mol/L, mmol/L, g/L, mg/L, µ g/L, ppm, ppb | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ± 0.5% | |
| Calibration Points | Up to 5 | |
| Conductivity | Range | 0.000 µ S/cm to 1000 mS/cm |
| Resolution | 0.001 µ S/cm minimum, various with range selection | |
| Accuracy | ± 1.0% FS | |
| Reference Temperature | 20, 25 ºC | |
| Calibration Points | Up to 3 | |
| Standard Recognition | 84 µ S/cm, 1413 µ S/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω ·cm~20.00 M Ω ·cm |
| Resolution | 0.01 Ω ·cm minimum | |
| Accuracy | ± 1.0% FS | |
| TDS | Range | 0.00 ppm~300 ppt |
| Resolution | 0.01mg/L minimum, various with range selection | |
| Accuracy | ± 1.0% FS | |
| Salinity | Range | 0.0~80.0 ppt |
| Resolution | 0.1ppt | |
| Accuracy | ± 2ppt | |
| Dissolved Oxygen Concentration – Polarographic | Range | 0.00 to 20.00 ppm |
| Resolution | 0.01 ppm | |
| Accuracy | ± 0.10 ppm | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation-Polaro-graphic | Range | (0.0 to 200.0)% |
| Resolution | 0.1% | |
| Accuracy | ± 2.0% | |
| Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ± 0.2 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 500 results each |
| GLP Features | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | PC |
| RS 232 | printer | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Power | AC Adapter, 100-240VAC input, DC9V output |
| Dimensions | 242 × 195 × 68 mm | |
| Weight | 900g (1.98 lb) | |

M300F Multi-parameter Analyzer PDF